dimmer shutter closed --> blackout (BO)
dimmer: you can perceive some light
dimmer
dimmer completely open
shutter immediatelly closed
shutter sequence 1 flash/sec upto 10 flashes/sec
shutter open
channel 6 = iris and gobo rotation
iris closed / gobo first position
iris open / gobo first position
second gobo position
third gobo position
..........
locked into position 360°
locked into position 540°
rotation left highest speed
rotation left lowest speed
rotation stop
rotation right slow
rotation right fast

Occupation DMX-In / DMX-Out

DMX-IN
Pin1:
ground
black
Pin2:
DMX-
beige
Pin3:
DMX+
red
Pin4:
free
Pin5:
+ 5V
green

Technical data

Measurements:
Weight:
Power consumption:
Mains Voltage:
Bulb
:
Fuse:

Change of Eprom/ Software Update

To change the Eprom proceed as follows:
Remove the cover sheet for the electronic board below the mirror by taking out the 4 screws (see sketch page 36). By
comparing the electronic board with the plan of electronic parts you can see the Eprom at the right side (IC U2). Carefully
lift out the used Eprom from the holder and change it for a new one.
®
4 1200 HMI
DMX-OUT
Pin1:
Pin2:
Pin3:
Pin4:
Pin5:
hight
100cm
width
34cm
depth
24cm
36 kg
ca. 1725W
230V 50Hz 7,5A
Osram 1200 HMI
16 ampere inert
DMX
0
DMX
19
DMX
20
-
127
DMX
128 -
137
DMX
138 -
139
DMX
140 -
243
DMX
244 -
255
DMX
0
DMX
-
64
DMX
65
DMX
66
DMX
191
DMX
191
DMX
192
DMX
222
DMX
223 -
224
DMX
225
DMX
255
ground
black
DMX-
beige
DMX+
red
free
free