Data logger function (LOG)
The IR-365RF is equipped with a data logger function. This function can be used to
save 20 measured values whilst measuring temperature, and these can then be
called up at a later time. The data logger function is only available for IR measured
values.
Saving temperatures:
Press the MODE key (3) until the function display (19) shows „LOG" (data logger) and
a memory slot (1-20). Use both the arrow keys (2/8) to select the memory slot in
which you wish to save data. If there is a temperature value already stored in the
memory slot, it is shown in the secondary display (20). If there is no saved value, „- -
- -" is displayed.
To save a temperature value in the selected memory slot, press the Laser/Back-
light/SET key during the temperature measuring process (key for temperature mea-
suring (7) pressed). The temperature value measured when the Laser/Backlight/SET
key (6) is pressed is stored. The saved temperature value is shown in the secondary
display (20). Values can also be saved when performing continual measurement.
Press the Laser/Backlight/SET key (6) to overwrite the memory slot with the current
measured temperature value.
Reading from the memory:
Press the MODE key (3) with the measuring device switched off until the function dis-
play (19) shows „LOG". The corresponding saved temperature value is shown in the
secondary display (20). You can call up the memory slots 1 - 20 using the arrow keys
(2/8).
Deleting the memory:
This function can be used to delete the entire memory (1-20) in a single process. Indi-
vidual memory slots cannot be deleted and can only be overwritten.
Press the MODE key (3) with the measuring device switched off until the function dis-
play (19) shows „LOG". Press and hold the temperature measurement key (7). Select
memory slot „0" using the arrow key „down" (8). Press the Laser/Backlight/SET key (6)
until you hear a beep. Release the temperature measurement key (7). The memory has
now been deleted.

Radio transmission of measured values to a computer

The IR-365RF is equipped with a 433 MHz radio transmission system for transferring
measured values to a computer. The measured values can thus be transferred to a
computer with a USB interface up to 10 m away and then saved and processed
using the software enclosed in the scope of delivery. This way, you can make long-
term records of temperatures in a simple manner.
- Press the arrow key „down" (8) in MAX/MIN/DIF or AVG mode to activate the data
transfer. „USB" appears in the display.
26
Eléments de commande
1
2
8
3
7
9
6
10
5
11
4
1. Affichage LCD
2. Flèche « up » (haut)
3. Touche « MODE »
4. Douille pour sonde de température
de type K
5. Logement des piles
6. Touche Laser/Backlight/Set
(rétroéclairage)
7. Touche de mesure de
la température
8. Flèche « down » (bas)
14
15 16
17
USB
25
21
22
18
23
24
19
20
13
26
27
12
30
29
9. Interrupteur à coulisse °C/°F
10. Interrupteur à coulisse mesure continue
11. Interrupteur à coulisse « Alarme
marche/arrêt »
12. Orifice du capteur infrarouge
13. Orifice de sortie du laser
26. Touche « ON »
27. DEL « ON »
28. Sortie analogique 1 mV/°C
29. Filet du trépied
30. Entrée 12 V pour adaptateur secteur
14. Indicateur de mesure
15. Affichage Data Hold
16. Mesure automatique de l'émissivité
17 Affichage de l'émissivité
18. Affichage des valeurs de température
19. Affichage des fonctions de l'écran
secondaire
20. Ecran secondaire
21. Affichage laser en marche et mesure
continue
22. Affichage °C/°F
23. Témoin d'usure des piles
24. Symbole d'alarme high/low
25. Symbole USB pour transmission
radio activée
28
35

Werbung

Kapitel

loading