• After a while, the thermometer switches off automatically to save battery power. You can
switch the device off manually at any time by pressing the ON/OFF key.
c) Measurement units
Turn the thermometer on and press the °C/°F key (7). Pressing this key changes the
measurement unit, which will be shown on the display.
d) MIN/MAX measurement
The minimum and maximum temperatures are automatically saved after each start-up.
These saved measurements can be displayed using the MIN/MAX key (4). When you press
this key, the display switches from the MIN value to the MAX value (or vice versa). After a few
seconds, the device automatically switches back to the normal measurement display.
The MIN and MAX values are deleted when the device is switched off.
e) Recording the displayed temperature
The thermometer can hold the measured value on the screen, making it easier to read.
1 Press the H/T key (5) during the measurement. The reading will be recorded and the
HOLD symbol will flash.
2 Press the H/T key again to switch back to the normal measuring mode.
f) Temperature limits
The thermometer allows you to set an upper (HI) and lower (LO) temperature limit. If the upper
limit is exceeded, or the temperature falls below the lower limit, an alarm tone will sound every
minute until the temperature is within the set range.
The two alarm levels can be set either simultaneously or separately. The alarm settings are
deleted as soon as the device is switched off.
• To set the upper alarm level, follow these steps:
1 Switch the thermometer on.
2 Hold the HI AL key (6) until the desired alarm value is displayed, and then release the key.
The HI symbol will be displayed to indicate that the HI alarm is enabled.
• To set the lower alarm level, follow these steps:
1 Switch the thermometer on.
2 Hold the LO AL key (8) until the desired alarm value is displayed, and then release the
key. The LOW symbol will be displayed to indicate that the LO alarm is enabled.
Note:
• Make sure that the two alarm levels do not overlap.
• The HI alarm value may not be lower than the LO alarm value, and the LO alarm value may
not be higher than the HI alarm value.

Care and cleaning

• Do not use any aggressive cleaning agents, rubbing alcohol, or other chemical solutions as
they can cause damage to the housing and functioning of the product.
• Clean the product with a dry, fibre-free cloth.
Disposal
a) Product
Electronic devices are recyclable waste and must not be disposed of in household
waste. At the end of its service life, dispose of the product in accordance with
applicable regulatory guidelines.
Remove any inserted (rechargeable) batteries and dispose of them separately from
the product.
b) (Rechargeable) batteries
As the end user, you are required by law (Battery Ordinance) to return all used
(rechargeable) batteries. Disposing of them in household waste is prohibited.
(Rechargeable) batteries containing hazardous substances are labeled with this
symbol to indicate that disposal in domestic waste is forbidden. The abbreviations
for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name
on (rechargeable) batteries, e.g. below the waste bin icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our
stores or wherever (rechargeable) batteries are sold.
You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical data

Power supply ................................... 2 x AAA battery (3 V)
Sensor probe length ........................ 144 mm (+ 120 mm handle)
Temperature range .......................... -50 °C to +300 °C
Temperature resolution .................... 0.1 °C (-19.9 °C to +199.9 °C)
1 °C (+200 °C to +300 °C)
Temperature accuracy ..................... ±1.0 °C (-30 °C to +25 °C)
Measuring frequency ....................... 1 second
Automatic cut-off .............................. Approx. 60 minutes
Operating temperature .................... -10 °C to +50 °C
Dimensions (W x H x D) .................. 72 x 137 x 25 mm
Weight ............................................. 170 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represent the technical status at the time of printing.
Copyright 2021 by Conrad Electronic SE.
*2380255_v1_0921_02_DS_m_4L_(1)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis