Rain
Pressing of the „Rain" key successively leads to the display of the Rain Volume of
the Last Hour (interval between the 30
hour), the Rain Volume of the Last 24 Hours (interval between 7.30h and 7.30h of
the respective day) and the Total Rain Volume (since start of measurements at
Setup respectivelly since last Reset) in the right center of the LCD.
Times and time intervals are in conformity with the International Rules for Profes-
sional Weather Services.
Basic display:
Press once:
Press twice:
Press three times:
If the "Reset" key is pressed for appr. 2 seconds during display of the Total Rain
Volume, the accumulated value of the Total Rain Volume will be erased and reset
to zero.
Time and date of the reset will be stored in the weather station's memory. Time and
date of the last reset can at any time be displayed by briefly pressing the "Reset"
key.
If during switching of the Rain Volume Mode from Total to 1h or from 1h to 24h the
„Rain" key is held down for a longer period of time, the display will switch to an
accumulating counter. This mode of operation is indicated in the display by the
symbol „r" in front of the numerical value. Now e.g. during a rain shower the „running
up" of the 1h resp. 24h counter can be observed.
Minimum/Maximum Function
The Min/Max function allows the display of the minimum and maximum values of
all measurements since the last reset of the Min/Max memory. If desired, the time
and date of the appearance of the respective minimum and maximum values can
also be displayed.
Display of the Minimum/Maximum Values
Press once:
Display of all Minimum Values
Press twice:
Display of all Maximum Values
Press three times:
During simultaneous display of all minimum or maximum values there will for the
present be no additional display of time and date. There will also be no weather
symbols, no display of air pressure tendency and no air pressure history. Instead
there will be the respective display MIN or MAX in the right center of the LCD.
If there is no DCF-77 time code reception or has the clock not been manually set,
then there will be no storage of any minimum or maximum values.
46
th
minute and the 30
Total Rain Volume
Rain Volume of the last Hour
Rain Volume of the last 24 Hours
Return to Total Rain Volume
(see illustration at right)
Return to Display of the Current Values
th
minute of the respective