17. Disposal

If the Professional Remote Weather Station happens to become inoperable and
must be disposed of please do this in accordance with the valid legal regulations.

18. Specifications

Measuring Interval Outdoor Sensor: ..............................................Appr. 3 minutes
Measuring Interval Indoor Sensor: .................................................Appr. 3 minutes
Transmission Frequency: ..................................................................... 433.92MHz
Transmission Distance in Open Field: .................................................. 100 m max.
Temperature Range Indoor: ........................................................... 0.0°C to +70°C
Temperature Range Outdoor: .....................................................- 30.0°C to +70°C
Resolution: ..................................................................................................... 0.1°C
Accuracy: ........................................................................................................±1°C
Measuring Range Rel. Humidity: ....................................................... 20% to 95%
Resolution: ........................................................................................................ 1%
Accuracy: .......................................................................................................... 8%
Measuring Range Air Pressure: ................................................... 800 to 1100 hPa
Resolution: .................................................................................................... 1 hPa
Accuracy: .................................................................................................... ±1 hPa
Air Pressure Variation: ............ Bar Diagram, Scaling 2 hPa/1,5 mmHg per Divider
Rain Volume Display: ....................................................................... 0 to 3999 mm
Resolution: .............................................................................................. < 0.5 mm
Accuracy: ............................................................................................... 2%±1 mm
Wind Strength: ................................................................................. 0 to 200 km/h
Resolution: ................................................................................................ 0.1 km/h
Accuracy: ............................................................................................. 3%±1 km/h
Wind Direction:Graphic Resolution 22.5 Degrees, Numerical Resolution 5 Degrees
Power Supply Base Station: ........... 4 x Type Mignon AA, IEC LR6, 1.5V (Alkaline)
Measurements Base Station (L x W x H): ................................ 165 x 30 x 337 mm