3. Specifications

Model
Noise level (50/60 Hz)
External static pressure
Indoor units
Total capacity
Model
Quantity
Operation
Standard type
temperature
Fresh air intake
type
Model
Noise level (50/60 Hz)
External static pressure
Indoor units
Total capacity
Model
Quantity
Operation
Standard type
temperature
Fresh air intake
type

4. Confirmation of parts attached

1 Conduit mounting plate (ø53)
Model
P200
P250 ~ P350
P400 ~ P650
5 Tapping screw M4
Model
P200
P250 ~ P350
P400 ~ P650

5. Space required around unit

[Fig. 5.0.1] (P.2)
<A> Top view
<C> When there is little space up to an obstruction
A Front
B No restrictions on wall height (left and right)
C Air outlet guide (Procured at the site)
E Wall height (H)
(mm)
L
L
1
2
450
450
(1) Basic space required
(2) When there is an obstruction above the unit
(3) When inlet air enters from right and left sides of unit
Wall heights "H" of the front and the back sides shall be within total height of
unit.
When wall height "H" exceeds total height of unit, add "h" dimension to L
L
of the Fig. 5.0.1.
2
"h" = wall height "H'" – total height of unit

6. Lifting method

[Fig. 6.0.1] (P.2)
Caution:
Be very careful to carry product.
- Do not have only one person to carry product if it weighs more than 20 kg.
- PP bands are used to pack some products. Do not use them as a mean for transportation because they are dangerous.
- Do not touch heat exchanger fins with your bare hands. Otherwise you may cut your hands.
- Tear plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic packaging bag may suffocate children to death.
- When carrying outdoor unit, be sure to support it at four points. Carrying with 3-point support may make outdoor unit unstable, resulting in it falling.
8
PU(H)Y-P200
PU(H)Y-P250
56 dB<A>
57 dB<A>
1 ~ 13
1 ~ 16
Cooling mode: – 5 °CDB ~ 43 °CDB (0 °CDB ~ 43 °CDB with outdoor unit at lower position)
Heating mode: – 20 °CWB ~ 15.5 °CWB
Cooling mode: 21 °CDB ~ 43 °CDB
Heating mode: – 12.5 °CWB ~ 20 °CWB
PUHY-P450
PUHY-P500
60/61 dB<A>
60/61 dB<A>
1 ~ 24
1 ~ 24
Cooling mode: – 5 °CDB ~ 43 °CDB (0 °CDB ~ 43 °CDB with outdoor unit at lower position)
Heating mode: – 20 °CWB ~ 15.5 °CWB
Cooling mode: 21 °CDB ~ 43 °CDB
Heating mode: – 12.5 °CWB ~ 20 °CWB
2 Conduit mounting plate (ø46)
1 pcs.
6 Connecting pipe (Flare)
2 pcs.
2 pcs.
2 pcs.
<B> Side view
D Must be open
F No restrictions on wall height
1
PU(H)Y-P300
59 dB<A>
0 Pa
50 ~130 %
20 ~ 250
1 ~ 19
PUHY-P550
61/62 dB<A>
0 Pa
50 ~130 %
20 ~ 250
1 ~ 24
3 Conduit mounting plate (ø33)
1 pc.
1 pc.
1 pc.
6 Connecting pipe (Flange)
1 pc.
1 pc.
1 pc.
(4) When unit is surrounded by walls
Note:
Wall heights "H" of the front and the back sides shall be within overall
height of unit.
If the panel height is exceeded, add the "h" dimension of the Fig. 5.0.1 to
L
and L
.
1
2
(mm)
L
L
1
2
450
450
Example: When the "h" dimension is 100 mm,
the L
dimension becomes 450 + 100 = 550 mm.
1
(5) Collective installation and continuous installation
Space required for collective installation and continuous installation:
When installing several units, provide the space between each block consider-
ing passage for air and people.
and
Open in two directions.
In case of wall height "H" exceeds total height of unit, add "h" dimension (h =
wall height "H'" – total height of unit) to * marked dimension.
If there is a wall at both the front and the rear of the unit, install up to four units
(Every 3 units in the case of P450 ~ P650.) consecutively in the side direction
and provide a space of 1000 mm or more as inlet space/passage space for
each four units (Every 3 units in the case of P450 ~ P650.) .
PU(H)Y-P350
PUHY-P400
60 dB<A>
1 ~ 20
PUHY-P600
PUHY-P650
61/62 dB<A>
62/62.5 dB<A>
1 ~ 32
4 Conduit mounting plate (ø27)
1 pc.
1 pc.
7 Packing (inside ø23, outsideø35)
1 pc.
1 pc.
61 dB<A>
1 ~ 22
1 ~ 32