Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Camille Bauer KINAX SR 709 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für KINAX SR 709:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

KINAX SR 709
Transmitter for position feedback

Technical data

Measuring input
Measured variable:
Measuring range limits:
Measuring output
Output variable I
:
A
Zero point correction:
Span adjustment:
Current limitation:
Standard ranges:
Non-standard ranges:
External resistance (load):
Residual ripple in
output current:
Accuracy
Linearity error:
2
Movement, stroke
0 ... 10 to 0 ... 140 mm
Load-independent DC current, pro-
portional to the input angle
Approx. ± 5%
Approx. + 5 / – 30%
I
max. 40 mA
A
0...1 mA/3 or 4-wire connection
0...5 mA/3 or 4-wire connection
0...10 mA/3 or 4-wire connection
4...20 mA/2-wire connection
or
0...20 mA/3 or 4-wire connection
(adjustable with potentiometer)
4...20 mA/3 or 4-wire connection
0...20 mA/4-wire connection
0...> 1.00 to 0...< 20 mA
3 or 4-wire connection
12 V
R
max. [kΩ] =
ext
I
[mA]
A
(for instruments with DC/AC power
supply by AC/DC power pack, with
electric isolation)
H [V] – 12 V
R
max. [kΩ] =
ext
I
[mA]
A
(for instruments with DC power
supply, without electric isolation)
I
= Output signal end value
A
< 0.3% p.p.
≤ 0.5%
Power supply H
DC and
AC voltage:
Table 1:
Nominal voltages U
N
24 ... 60 V DC/AC
85 ... 230 V DC/AC
Power consumption:
Power supply
effect on accuracy:
1
DC voltage only
:
Max. residual ripple:
Max. current consumption: Approx. 5 mA + IA
Power supply
effect on accuracy:
Mechanical withstand
Permissible vibration:
Shock:
Mounting position:
Housing data
Material:
Cable glands:
1
Polarity reversal protection. The voltage must not fall below 12 V.
Nominal voltages and tolerances see
"Table 1"
Tolerances
DC – 15 ... + 33%
AC ± 15%
only possible with
standard version, non-Ex,
with electric isolation,
with AC/DC power pack
(DC and 45 ... 400 Hz)
< 0.9 W resp. < 1.8 VA
≤ 0.1% within the admissible power
supply tolerance
12 ... 33 V
(possible with standard version, non-
Ex, without electric isolation)
12 ... 30 V
(necessary with Ex version, type
of protection "Intrinsic safety"
EEx ia IIC T6, without electric
isolation)
10% p.p.
< 0.2% within the admissible power
supply tolerance
20 ... 200 Hz,
10 g continuous, 15 g for 2 h
200 ... 500 Hz,
5 g continuous, 10 g for 2 h
3 × 50 g every 10 impulses
in all 3 axes
Any
Metal (aluminium)
2 cable glands PG 11 in metal
Camille Bauer

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis