4. Main features

• Robust transmitter for angular position suitable for fi eld
applications
• Highest degree of mechanical and electrical safety
• Proven capacitive scanning system
• No wear, low annual maintenance and mountable any-
where
• Vibration- and shock-resistant
• Measuring range, sense of rotation, zero position and
linear/V characteristic can be adjusted by a switch and
two push-buttons
• Analog output signal 4...20 mA, 2-wire connection
• Zero position and end position are independently adju-
stable
• Capacitive scanning system provides absolute position
immediately after activation
• With explosion prevention „Ex ia IIC T4 Gb",
„Ex ia IIIC T80°C Db" and
„Ex tb IIIC T80°C Db" according to ATEX and IECEx
available
• With GL (Germanischer Lloyd) available

5. Technical data

5.1 General
Measured quantity:
Angle of rotation
Measuring principle:
Capacitive method
Differential screen capacitor with
contact-free, non-wearing posi-
tional pick-up. Drive shaft fully
rotatable without stops
5.2 Measuring input
Angle measuring range: Programmable between
0 ... 360°
Hollow-shaft diameter: 30 mm, by reduction 10, 12, 16 or
20 mm
Starting torque:
max. 0.7 Nm
Sense of rotation:
Adjustable for sense of rotation
clockwise or counterclockwise
5.3 Measuring output
Overvoltage category:
II
Power supply:
Standard NEx:
nominal voltage 24 VDC
protected against wrong polarity
Explosion protection intrinsic ia:
12...30 VDC
protected against wrong polarity
(30 V must not be exceeded and
don't go below 12 V)
Explosion prevention (Protection by
enclosure) tb:
nominal voltage 24 VDC
protected against wrong polarity
max. input voltage U
:
30V
i
max. input current I
:
160mA
i
max. input power P
:
1W
i
max. internal
capacitance C
:
22nF
i
Camille Bauer
max. internal
inductance L
Output variable I
Max. residual ripple:
Standard range:
Response time:
External resistance:
5.4 Accuracy data
Error limit:
Reproducibility:
Angle step (hysteresis): linear:
Infl uence of temperature
output current
(–40°...+85°C):
5.5 Installation data
Material:
Mounting position:
Connections:
Weight:
5.6 Regulations
Immunity:
Spurious radiation:
Test voltage:
Admissible
common-mode voltage: 100 V, 50 Hz
+30%
-50%
Housing protection:
5.7 Environmental conditions
Climatic rating:
+30%
-50%
Transportation and
storage temperature:
Vibration resistance:
Operating Instructions HW730 Be
:
7.3 μH
i
:
Load-independent DC current,
A
proportional to the input angle
< 0.3% p.p.
4 ... 20 mA, 2-wire
< 3.5 ms
R
[kΩ] =
ext max.
H = Power supply
I
= Output signal end value
A
< ± 0.35°
< 0.1°
measuring range < 180°: 0.025°
measuring range ≥ 180°:
0.05° · measuring range
360
V-characteristic: 0.025°
± 0,4 ‰ / 10K
Housing: anodized aluminium
Any
Spring-type terminal block or
sensor plug connector metal
(M12 x 1 / 4 poles / only for NEx
version)
Approx. 820 g
The EN 61 000-6-2 is observed
Surge capacity acc.
EN 61 000-4-5:
1 kV, 1.2/50 μs
EN 61 000-6-3 and EN 61 000-6-4
750 V DC, 1 min.
All connections against housing
IP 67 acc. to EN 60 529
IP 69k acc. to EN 40 050-9
Standard NEx:
Temperature – 40 to + 85 °C
Rel. humidity ≤ 95%
non-condensing
Explosion prevention:
Temperature -40 to 75 °C
Rel. humidity ≤ 95%
non-condensing
– 40 to + 85 °C
2
≤ 100 m/s
/ 10 – 500 Hz
acc. IEC 60068-2-6
H [V]-12V
I
[mA]
A
15