Herunterladen Inhalt Inhalt Diese Seite drucken

Resetting The Total Lamp Timer - Sharp PG-MB60X Service Anleitung

Vorschau ausblenden Andere Handbücher für PG-MB60X:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

RESETTING THE TOTAL LAMP TIMER

● Resetting the total lamp timer
When replacing the lamp, reset the total lamp timer in the procedure below.
Info
Make sure to reset the lamp timer only
·
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.
1
Connect the power cord.
Plug the power cord into the AC socket
·
of the projector.
2
Reset the lamp timer.
While simultaneously holding down
·
and on the projector, press on
the projector.
ÒLAMP 0000HÓ is displayed, indicating
·
that the lamp timer is reset.
Lamp
■ It is recommended that the lamp (sold separately) be replaced when the remaining lamp life becomes 5% or less,
or when you notice a significant deterioration in the picture and color quality. The lamp life (percentage) can be
checked with the on-screen display.
■ Purchase a replacement lamp of type AN-MB60LP from your place of purchase, nearest Sharp Projector Dealer or
Service Center.
■ The warning lights (ON/STANDBY button, lamp indicator and temperature warning indicator) on the projector
indicate problems inside the projector.
■ If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate red, and the
projector will enter the standby mode. After the projector has entered the standby mode, follow the procedures
given below.
About the temperature warning indicator
If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,
Ò
Ó will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp will
turn off and the temperature warning indicator will blink, the cooling fan will run for a further 90 seconds, and
then the projector will enter the standby mode. After Ò
described on operation manual.
,
"
Maintenance Indicators
Power indicator
Lamp indicator
Temperature warning indicator
PICTURE MODE
Ó appears, ensure to perform the measures
23
AC socket
ON button
ENTER button
"
button
MENU button
PICTURE MODE
PG-MB60X

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis