EN
• Repair and maintenance work may be effected
by electrically skilled personnel only.
• To ensure perfect function of the devices, the proper function of
the compressed air supply has to be checked on a regular basis.
• Risk of injury due to unexpected air outlet!
• Disassemble and install components very care-
fully! Exclusively use included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, lyes, bases, pickling agents, unsuitable
regenerates or other aggressive cleaning solutions!*
• Immersing the SATA anti dust jet / X into cleaning agent
or using a spray gun washing machine is prohibited!*
• Risk of combustion!
The solvent must have completely evapo-
rated prior to further operation.
ATTENTION!
• Please clean the drillings with SATA cleaning brushes
and SATA nozzle cleaning needles only. The use of
other tools may cause damages and malfunction. Recom-
mended accessories: cleaning kit Art. No. 64030.
• Never use ultrasonic cleaning systems
- damaged nozzles and surfaces!*
• The emission points [7-1] of the electrode
[1-13] must not be damaged.
• These types of work may only be ef-
fected outside of the ex-area.
* otherwise damage and malfunction
• To ensure proper function of the SATA anti-dust jet / X, please
clean the discharge electrode [1-13] with oil and water-free
compressed air (e.g. SATA blow gun Art. No. 15156) and a brush
with either PVC or soft copper bristles at least once a week.
• To avoid contamination of the nozzles [7-2] during clean-
ing of the rotating nozzle [1-1], the blow air (< 0.5 bar)
must be switched on during the cleaning process.