Herunterladen Inhalt Inhalt Diese Seite drucken

Miscellaneous Commands - Magtrol DSP7000 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Kapitel 7 – Rechnergesteuerter Betrieb
7.4.7
m
iScellAneouS
Command
Code
Channel 1
FRZ1,#
I1
I1,xx.xx
IO1,xx.xx
SAVE,#
MODE#
OS,#
OV,#
TS1
TR1
TMV1,#
c
ommAndS
Command
Code
Channel 2
FRZ2,#
Freezes the PID loop.
I2
Reset Current output to 0.00%
I2,xx.xx
Sets current output to xx.xx%. The power supply outputs
IO2,xx.xx
Sets current offset. (sums
xx.xx% to output of DAC)
SAVE,#
Saves present configuration of
unit to non-volatile memory.
MODE#
Allows the user to swtich from
7000 mode to 6001 mode and
back.
OS,#
Read speed in four decimal
digits.
OV,#
Reads voltage applied to A/D
channel in mV.
TS2
Enables tare function.
TR2
Disable tare function.
TMV2,#
TM torque reading invert flag
78
Magtrol DSP7000-Leistungsbremsen-Controller
Function
Values for # are:
0 = off
1 = freeze PID
a fixed value of current.
Use any value # between 0
and 99.99%. (99.99% = 1
Amp).
Values for # range from 0
to 99.99.
Values for # are:
0 = main board
1 = DSP7002 board
2 = I/O Card 1
3 = I/O Card 2
Values for # are:
0 = 7000 mode
1 = 6001 mode
Values for # are:
1 = Channel 1
2 = Channel 2
Values for # are:
1 = Channel 1
2 = Channel 2
3 = I/O Card 1 channel 1
4 = I/O Card 1 channel 2
5 = I/O Card 2 channel 1
6 = I/O Card 2 channel 2
Values for # are:
0 = Normal
1 = Invert
Explanation

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Magtrol DSP7000

Inhaltsverzeichnis