Operating Instructions SATAjet 1000 B RP/HVLP
• The following applications and operations lead to the loss
of the explosion protection and are, therefore, prohibited:
• Use of the paint spray gun in explosive areas belonging to ex-zone 0!
• Do not use solvents and cleaning agents based on halogenised
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
7.

Use

• Use only solvent-resistant, antistatic, undamaged and technically flaw-
less compressed air hoses with a permanent pressure resistance of
minimum 10 bar, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Use a compressed air connection G 1/4 a or a fitting SATA connection
nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Clean compressed air, i.e. with SATA filter 100, Art. No. 148247,
outside the spray booth or SATA filter 484, Art. No. 92320 in-
side the spray booth
• Use an air hose with minimum 9 mm inner diameter (see warnings),
e.g. Art. No. 53090.
43. Check if all screws [2-1], [2-2], [2-3], [2-4] and [2-5] have been
tightened firmly. Tighten fluid tip [2-1] firmly by hand (14 Nm) accord-
ing to [7-4]. Check if locking screw [2-5] has been firmly tightened
according to [10-1]. Tighten, if necessary.
44. Rinse material passages with suitable cleaning solution [2-6], ob-
serve chapter 8.
45. Adjust air cap: vertical spray fan [2-7], horizontal spray fan [2-8].
46. Insert paint strainer [2-9] and install gravity flow cup [2-10].
Warning! Risk of explosion!
Warning! Risk of explosion!
Notice!
EN
107

Werbung

Inhaltsverzeichnis
loading