Note:
1.
When the input is not connected, i. e. at open circuit, the
figure "1" will be displayed for the overrange condition.
2.
There is 1 mA current flow through the device under test
3.
The meter displays the forward voltage drop in millivolts,
and overload when the diode is reversed.
6.7. Battery Test
1.
Insert the black test lead banana plug into the negative COM
jack and the red test lead banana plug into the positive V jack.
2.
Select the 1,5V or 9V BAT position using the function select
switch.
3.
Connect the red test lead to the positive side of the 1,5V or 9V
battery and the black test lead to the negative side of the 1,5V
or 9V battery.
4.
Read the voltage in the display.
Good
9 V battery
>8,2 V
1,5 V batttery
>1,35 V
6.8. Non-Contact Voltage (NCV)
The NCV function works on any rotary switch position.
1.
Test the detector on a known live circuit before use.
2.
Hold the top of the meter very close to the voltage source as
shown.
3.
If voltage is present, the rim of the LCD display will flash a
bright red.
Weak
Bad
7,2 to 8,2 V
<7,2 V
1,22 to 1,35 V
<1,22 V