19. Removing the belt in the event of unit failure

In the event that the RolloTron Swivel Winder Comfort
unit fails and the motor no longer runs, you can use the
disengaging bracket provided in order to fully remove
the belt from the belt winder unit, without the need for
cutting it.
There is a risk of injury as the roller shutters may slam
shut or fall in an uncontrolled manner.
◆ Secure the roller shutters from falling, for example,
by laying something underneath it.
◆ Hold on to the belt tightly to stop the roller shutters
from slamming shut or falling in an uncontrolled
manner.
◆ Get a second person to help you unlatch the unit.
1.
2.
3.
Release the drive with the help of the supplied disen-
gaging bracket. A small amount of resistance must be
overcome when pressing.
110
WARNING!
Remove the mains plug from the
socket.
Turn the RolloTron Swivel Winder
Comfort completely to the side.
4.
Maintain pressure on the disengaging bracket and pull
the belt out of the RolloTron Swivel Winder Comfort as
far as possible.
Drive release
5.
Remove the reel compartment cover. Release the belt
from the fastening hook and pull it out completely from
the RolloTron Swivel Winder Comfort.
6.
Press the assembly locking device on the back part
and pull remove the RolloTron Swivel Winder Comfort
from the wall bracket by pulling it downwards.
7.
Place the disengaging bracket back into the storage
compartment.