Herunterladen Inhalt Inhalt Diese Seite drucken

Removing The Belt In The Event Of Unit Failure - RADEMACHER 1823 45 19 Betriebsanleitung

Rollotron basis1100
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

i

18. Removing the belt in the event of unit failure

In the event that the RolloTron Basic 1100 unit fails and
the motor no longer runs, you can use the disengaging
bracket provided in order to fully remove the belt from
the belt winder unit, without the need for cutting it.
1.
2.
Dismantle the RolloTron Basic 1100 as previously
demonstrated on page 75.
There is a risk of injury as the roller shutters may slam
shut or fall in an uncontrolled manner.
◆ Secure the roller shutters from falling.
◆ Hold on to the belt tightly to stop the roller shutters
from slamming shut or falling in an uncontrolled
manner.
◆ Get a second person to help you unlatch the unit.
Remove the mains plug from the
socket.
WARNING!
3.
Release the drive with the help of the supplied disen-
gaging bracket. A small amount of resistance must be
overcome when pressing.
4.
Maintain pressure on the disengaging bracket and pull
the belt out of the RolloTron Basic 1100 as far as possible.
5.
Release the belt from the fastening hook and pull it
out completely from the RolloTron Basic 1100.
6.
Replace the disengaging bracket in its holder.
Drive release
Storage bay
EN
77

Werbung

Kapitel

Inhaltsverzeichnis
loading