The manufacturer shall not be liable for any damage to the condenser unit resulting from failure to keep
the condenser clean!
(Applies to Gastroline Cube 0.6)The door seal must only be cleaned with fresh water with no addition of
detergents. Remember to dry it carefully.
The seal cannot come into contact with greasy substances or oils!
While following the maintenance procedures ensure that the door closes properly.
For Example: Place a piece of paper between the seal and the casing then close the door. If the
seal is working properly, the paper should be difficult to move at any attempt of removing it.
Components of the device can corrode due to improper use and maintenance.
Please follow the rules:
• Do not allow surfaces of the unit to come into contact with chlorine and/ or soda in different forms.
Such agents destroy the protective layer and components of the device (applies also to different
types of stainless steel).

Fig.10 Replacing bulbs in the lamp

1 – Handle of the lamp
2 – LED lamp
3 – Light luminaire
While carrying maintenance of the device make sure you do not damage the rating plate of the device
Fig. 11 (p. 20) , which contains important information for technicians and companies that deal with waste
disposal.

6. SERVICE

6.1. Defect identification and repair

If you have any difficulties while turning on or during the operation of the unit, you should refer to the relevant chapters
in the Operating Manual that explain the performed operation. This will ensure that the unit is properly operated. If diffi-
culties persist, the following guidelines might be helpful in their removal:
If the unit is not working...- Make sure that:
• The unit is connected to the electricity supply.
• The voltage and frequency of the electricity supply are the same as those recommended by the manufacturer
(see rating plate)
• The main switch is on
• The thermostat is switched on (Applies to Igloo thermostat – If the screen displays only two dots
- turn the thermostat on)
The unit is working, but the lights are not on ...- Make sure that:
• The light switch is on
• Check whether the LED lamps plugs are properly pluged-in