Eliminating minor faults yourself

Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following information.
Customer service will charge you for advice – even if the appliance is still under guarantee!
Fault
Temperature differs greatly
from the set value.
Displays do not illuminate.
Temperature display indicates
"E..".
Warning signal sounds, alarm
button Ú is lit.
The freezer compartment is
too warm!
Frozen food is at risk!
The temperature display for
the freezer compartment
flashes, a warning signal
sounds and the alarm
button Ú is lit.
The freezer compartment
is too warm!
Frozen food is at risk!
Temperature display for
the freezer compartment
flashes.
Appliance is not cooling,
temperature display and light
are lit.
x
Possible cause
Power failure; the fuse has been
switched off; the mains plug
has not been inserted properly.
Electronics have detected a fault.
Appliance is open.
Ventilation openings have been
covered.
Too much food was placed
in the freezer compartment at once.
Appliance is open.
Ventilation openings have been
covered.
Too much food was placed
in the freezer compartment at once.
A fault caused the freezer
compartment to become too warm
in the past.
Showroom mode is switched on.
Remedial action
In some cases it is adequate to switch off
the appliance for 5 minutes.
If the temperature is too high wait a few hours
and check whether the temperature has approached
the set value.
If the temperature is too low check the temperature
again the next day.
Connect mains plug. Check whether the power
is on, check the fuses.
Call customer service.
To switch off the warning signal, press the alarm
button Ú.
Close the appliance.
Ensure that there is adequate ventilation.
Do not exceed max. freezing capacity.
When the fault has been eliminated, the alarm
button Ú goes out shortly afterwards.
To switch off the warning signal, press the alarm
button Ú.
Close the appliance.
Ensure that there is adequate ventilation.
Do not exceed max. freezing capacity.
When the fault has been eliminated, the alarm
display goes out shortly afterwards.
When the alarm button Ú is pressed,
the temperature display stops flashing.
The temperature display indicates for 5 seconds
the warmest temperature which was reached
in the freezer compartment.
Start appliance self-test (see chapter "Appliance
self-test").
When the programme has ended, the appliance
switches over to normal operation.