Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - clage SMARTRONIC MCX 3 Gebrauchs- Und Montageanleitung

Vorschau ausblenden Andere Handbücher für SMARTRONIC MCX 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
MCX 3..7 SMARTRONIC ®

3. Technical specifications

Typ
Art. No.
Capacity
EN
Nominal pressure
Heating system
Required water resistance
at 15 °C in Ω cm
Electric supply
Nominal power rating
Nominal current
Temperature choice
Factory temperature setting
Maximum inlet temperature
Factory flow setting at 3 bar
Maximum temperature
increase at rated power and
a flow rate of...
1)
Required l/min to switch on
Required l/min to switch off
Min. required cable size
Weight filled with water
Dimensions (H × W × D)
Protection class acc. to VDE
Type of protection according to VDE
1) Temperature rise (Kelvin) + cold-water temperature = maximum hot-water temperature (°C) ≤ 70 °C
2) The cable size must not exceed 4 mm
Liter
MPa (bar)
2,0 l/min
2,0 l/min
2,5 l/min
3,0 l/min
3,5 l/min
4,0 l/min
l/min
l/min
mm
2)
2
2
MCX 3
MCX 4
15003
15004
0,2
0,2
1 (10)
1 (10)
Bare wire heating system IES ®
≥ 1100
≥ 800
1~ / N / PE 220 – 240 V AC
3,5 kW
4,4 kW
15 A
19 A
35 °C – 38 °C – 45 °C
38 °C
38 °C
70 °C
70 °C
2,5 l/min
25 K
31 K
20 K
25 K
17 K
21 K
14 K
18 K
12 K
16 K
1,2
1,5
1,0
1,3
1,5
2,5
13,5 × 18,6 × 8,7 cm
20
MCX 6
MCX 6-220
15006
15005
0,2
0,2
1 (10)
1 (10)
≥ 800
≥ 800
1~ / N / PE
220 V AC
5,7 kW
6,0 kW
25 A
27 A
38 °C
38 °C
70 °C
70 °C
3,3 l/min
4,5 l/min
41 K
43 K
33 K
34 K
27 K
29 K
23 K
24 K
20 K
21 K
1,5
1,5
1,3
1,3
4,0
4,0
ca. 1,5 kg
1
IP 25
MCX 7
15007
0,2
1 (10)
≥ 1100
2~ / PE
400 V AC
6,5 kW
16 A
38 °C
70 °C
3,7 l/min
46 K
37 K
31 K
26 K
23 K
1,5
1,3
2,5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Smartronic mcx 7Smartronic mcx 4Smartronic mcx 6Smartronic mcx 6-220Mcx 3Mcx 4 ... Alle anzeigen

Inhaltsverzeichnis