Defining a code
• Select Function
.
• Press the START/STOP button for 3 seconds until
• Press the desired buttons consecutively:
• Press the buttons in the same sequence when
again.
•
appears in the display. The set code has been saved.
• Please note the code for Customer Service.
If you know the old code, you can define a new code at any time. We re-
commend that you already set a new access code during the initial start-
up.
138
Calibrating the sensor
The sensor must be recalibrated every 30 working days, so that the
user's tanning type can be determined reliably and the power of the UV-
appears.
lamps can be optimised for the tanning type.
The calibration page can be found at the back of this operating manual.
appears
Caution!
Sensor failure / automatic operation fault is possible.
You must ensure that the sensor is positioned precisely above
the calibration tip during calibration. Switch off any bright light
sources (e.g. halogen beams) if necessary.
• Select Function
• Calibration: See description given at the back of the operating manu-
al.
Note:
Inform the customer service department if a false calibration
keeps on occurring.
in presetting mode.