pressure hose. These media destroy the pressure
hose.
• The work area must be separated from the compres-
sor so that it cannot come into direct contact with the
working medium.
Operation of pressure vessels
• Anyone who operates a pressure vessel must keep
this in good working order, operate and monitor it
correctly, perform the necessary maintenance and
servicing works immediately and implement safety
measures as required according to the circumstances.
• The regulatory authority can instruct necessary
monitoring measures in individual cases.
• A pressure vessel must not be operated if it exhibits
a defect that poses a danger to personnel or third
parties.
• Check the pressure vessel for rust and damage
each time before use. The compressor shall not be
operated if the pressure vessel is damaged or rusty.
If you discover damage, please contact the custom-
er service workshop.
Residual risks
The product has been built according to state-of-the-
art and the recognised technical safety rules. Howev-
er, individual residual risks can arise during operation.
Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
• Residual risks can be minimised if the "Safety In-
structions" and the "Intended Use" together with the
operating instructions as a whole are observed.
• Use the tool attachment that is recommended in this
operating manual. This is how to ensure that your
product provides optimum performance.
• Keep your hands away from the working area when
the product is in operation.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
• Avoid accidental starting of the product: the oper-
ating button may not be pressed when inserting the
plug in a socket.
8. Before commissioning
• Before connecting, make certain that the data on the
type plate matches with the mains power data.
• Prior to initial commissioning, remove the transport
plug (9d) and fill the compressor pump housing with
oil as described in item 9.4.
• Install the compressor near the point of consumption.
30 | GB
• Long air lines and supply cables (extension cable)
should be avoided.
• Ensure that the intake air is dry and dust-free.
• Do not deploy the compressor in damp or wet areas.
• Operate the compressor only in suitable areas (well
ventilated, ambient temperature +5°C to 40°C).
There must be no dust, acids, vapours, explosive
gases or inflammable gases in the room.
• The compressor is designed to be used in dry
rooms. It must not be used in areas where splashed
water is present.
• The oil level in the compressor pump must be
checked before commissioning.
• The compressor may only be used outdoor briefly
when the ambient conditions are dry.
• The compressor must always be kept dry and must
not be left outdoors after work is complete.
9.
Assembly and operation
m WARNING
Always make sure the product is fully assembled
before commissioning!
m WARNING
Danger of injury!
Do not insert the mains plug into the socket until you
are ready to use the product.
Required tool:
• Open-ended spanner, size 13 mm*
• Open-ended spanner, size 17 mm*
• Phillips screwdriver*
* Not included in the scope of delivery
9.1
Fitting the wheels (fig. 3)
• Fit the wheels (8) provided as shown.
• Use an open-ended spanner AF 17 mm for this (not
included in the scope of delivery).
9.2
Fitting the foot (Fig. 4)
• Fit the foot (6) provided as shown in.
• Use an open-ended spanner AF 13 mm for this (not
included in the scope of delivery).
9.3
Installing the air filter (fig. 5, 6)
NOTE
The air filter must be fitted before commissioning.
Operating without the air filter damages the com-
pressor and voids the warranty.
www.scheppach.com