11. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The custom-
er's mains connection as well as the extension ca-
ble used must also comply with these regulations.
When working with spray attachments and during tem-
porary use outdoors, the product must be connected
to a residual current circuit breaker with a trigger
current of 30 mA or less.
11.1 Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
11.2 Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
socket.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
11.3 AC motor
• Before commissioning, ensure that the mains volt-
age matches with the operating voltage on the type
plate.
26 | GB
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm².
Connection type X
If the mains connection cable of this product is dam-
aged, it must be replaced by a specially prepared
mains connection cable which can be obtained from
the manufacturer or its service department.
12. Cleaning, maintenance and storage
m Attention!
Pull out the mains plug before carrying out any clean-
ing or maintenance work! Danger of injury due to elec-
tric shocks!
m Attention!
Wait until the product has cooled down completely!
Danger of burning!
m Attention!
Depressurise the product before carrying out any
cleaning or maintenance work! Danger of injury!
12.1 Cleaning
• Keep the product as free of dust and dirt as possible.
Rub the product clean with a clean cloth or blow it off
with compressed air at low pressure.
• We recommend that you clean the product directly
after every use.
• Clean the product at regular intervals using a damp
cloth and a little soft soap. Do not use aggressive
cleaning agents or solvents; they could attack the
plastic parts of the product. Make sure that no water
can penetrate the product interior.
• The hose and injection tools must be disconnected
from the compressor before cleaning. The com-
pressor must not be cleaned with water, solvents or
similar.
12.2 Maintaining the pressure vessel (fig. 1)
Attention!
To ensure a long service life for the pressure vessel (9),
drain off the condensate after each use by opening the
drain screw (11).
Release the vessel pressure beforehand (see 12.6.1).
The drain screw (11) is opened by turning it anti-clock-
wise (when looking at the screw on the bottom of the
compressor) so that the condensate can be completely
drained out of the pressure vessel (9).