Herunterladen Inhalt Inhalt Diese Seite drucken

System Connection M23 For C4000 Fusion - SICK C4000 Advanced M23 Betriebsanleitung

Safety light curtain
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Chapter 2
Fig. 2: Pin assignment
system connection M23
Tab. 2: Pin assignment
system connection M23
16
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Electrical installation
2.1.2

System connection M23 for C4000 Fusion

3
4
5
11
2
1
10
9
8
Pin
Wire colour
Sender
1
Brown
24 V DC input (voltage supply)
2
Blue
0 V DC (voltage supply)
3
Grey
Test input (sender test
4
Pink
Reserved
5
Red
Reserved
6
Yellow
Reserved
7
White
Reserved
8
Red/blue
Reserved
9
Black
Device communication (EFI
10
Purple
Device communication (EFI
11
Grey/pink
Reserved
12
Green
Functional earth
2)
In the default delivery status the sender test function is deactivated. It can be activated using the CDS. (See
the original operating instructions "C4000 Standard/Advanced", section 6.12 "Test input (sender test)" or the
original operating instructions "C4000 Entry/Exit", section 6.8 "Test input (sender test)".)
6
7
12
2)
)
0 V: external test active
24 V: external test inactive
A
B
Addendum Operating Instructions
C4000 Advanced M23
C4000 Entry/Exit M23
3
4
5
2
1
10
9
Receiver
24 V DC input (voltage supply)
0 V DC (voltage supply)
OSSD1 (output signal switching
device 1)
OSSD2 (output signal switching
device 2)
Reset/restart
External device monitoring
(EDM)
Application diagnostic output
(ADO)
Output Reset required
)
Device communication (EFI
)
Device communication (EFI
Reserved
Functional earth
8010834/VH46/2011-09-13
Subject to change without notice
C4000 Fusion
11
6
7
12
8
)
A
)
B

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

C4000 entry/exit m23C4000 fusion