19. FUEL OIL CONSUMER INSTALLATION DECOMMISSIONING
For the decommissioning of fuel oil consumer installations, proceed as follows:
• Switch the operation and heating main switch off
• Close the oil shut-off device
If both sides of the line are blocked, the pressure may rise due to temperature-related
changes in the volume of the fuel oil. For longer periods of decommissioning, e.g. for
fuel oil consumer installations without water heating, we recommend the installation
of safety equipment to protect against overpressure in suction lines, e.g. pressure
compensation valve type DAV7 part no. 15 550 00 or pressure compensation valve
type DAV7P part no. 15 550 15 to protect against overpressure in pressure lines.
For decommissioning in seasons with a risk of frost, the fuel oil consumer installation should
be properly emptied.
20. DISPOSAL
To protect the environment, our products may not be disposed of along with
household waste. In order to protect the environment, our products may not be
disposed of along with household waste and products contaminated with
water-hazardous substances or that have come in contact with such
substances must not be disposed of in the domestic waste, to public waters or
channels.
The product must be disposed of via local collection stations or a recycling station.
21. TECHNICAL DATA
Maximum admissible pressure PS
Maximum admissible pressure PS
Ambient temperature
Housing material
22. WARRANTY
We guarantee that the product will function as intended and will not leak during
the legally specified period. The scope of our warranty is based on Section 8 of
our terms and conditions of delivery and payment.
23. TECHNICAL CHANGES
All the information contained in this assembly and operating manual is the result of product
testing and corresponds to the level of knowledge at the time of testing and the relevant
legislation and standards at the time of issue. We reserve the right to make technical changes
without prior notice. Errors and omissions excepted. All figures are for illustration purposes
only and may differ from actual designs.
24. CERTIFICATE
Our management system is certified according to ISO 9001, ISO 14001 and
ISO 50001, see:
www.gok.de/qualitaets-umwelt-und-energiemanagementsystem.
12 / 24
Shut-off valve type RV and regulating valve
16bar
4bar (for Female thread, cylindrical ( LPG))
-20°C bis +60°C
brass CW617N
Regler- und Armaturen-Gesellschaft mbH & Co. KG
Obernbreiter Straße 2-18 • 97340 Marktbreit / Germany
Tel.: +49 9332 404-0 • Fax: +49 9332 404-43
E-Mail: info@gok.de • www.gok.de • www.gok-blog.de
Artikel-Nr. 02 230 50 b