4.
You may configure certain operating parameters of a connected chlorinator form your RC
module. The logic of the chlorinator menu is the same as that of DIN module. Press the "V"
button to enter the chlorinator unit main configuration
Setpoint pH
Press "V" button to move down in the menu,
a.
>Setpoint RX
Press "ꓥ" button to move up in the menu,
Max. power
b.
Cell voltage
The ">" arrow indicates the selected parameter,
c.
Salinity
d.
>Warnings
Alarms
Operation mode
Pasmo alarmu PH
The "Setpoint PH" menu allows the user to change pH settings of the chlorinator
5.
Setpoint pH
>
7.2
Note:
You may adjust the value of the RX parameter exactly the same way. Cancel any unwanted changes by pressing the "ENT/ESC"
button. The default code for parameter changes is "1234". The code may be changed only by a pool professional with a service
module. When a wrong code is entered, changes will not be saved and the unit will return to its default screen.
The "Max. power" menu allows the user to limit the maximum output of the salinator cell (0-
6.
100%):
Max. power (%)
80 %
The "Cell voltage" menu displays the actual potential on the salinator cell:
7.
Cell voltage (V)
3,5 V
Read only
(%)
(V)
Select ">Setpoint PH" and press "ENT/ESC" button,
a)
Press "SET/SEND" to activate pH setting mode,
b)
Press "V" to decrease pH value (1 click = -0,1 pH),
c)
Press "ꓥ" to increase pH value (1 click = +0,1 pH),
d)
Press "SET/SEND" to confirm and send changes to DIN module,
e)
An "OK" message will appear at the bottom right of the display.
f)
Select ">Max. power" and confirm with "ENT/ESC",
a)
Press "SET/SEND" to activate value adjustment,
b)
Press "V" to lower power (-1 % / 1x click),
c)
Press "ꓥ" to increase power (+1 % / 1x click),
d)
Press "SET/SEND" to confirm and send changes to DIN
e)
An "OK" message will appear at the bottom right of the
f)
Select ">Cell-potential" and confirm with "ENT/ESC",
a)
The parameter is only informative - "Read only", it cannot be adjusted.
b)
menu:
Press the "ENT/ESC" key to enter the selected parameter menu.
Flashing orange rectangle on the display indicates ongoing
information transfer between the DIN/RC modules and the
dosing unit – wait for the communication to finish in order to
change the parameter setting.
unit:
module,
display.
12