5. The "Lights" and "Atr/Atr 2" menus allow the user to set operating timers for
these outputs with a 15 min. step (0-120 for Atr, 0-240/ON for Lights):
Lights
015min
Lights
045min
Lights
075min
Lights
120min
Note:
The quick-access F1 button (Lights by default) also allows permanent ON ((000 – ON – 015 – 030 ... 240 min).
6. The "Heating/Cooling" menu allows the user to set the heating / cooling and water
temp.:
29°C
Heating
27°C
Cooling
Filtration
Dosing
Temperature25°C
Lights
Atr
Note:
Preset output delay – in this case 8 mins remain to heating power ON (preset delay 10) and allowed operating temperature
range are preset in the system. These technology-protecting parameters can be modified only by authorized person.
The heating priority function can be configured with DIP Switch 4. With heating priority deactivated, heating/cooling may
be active only when the filtration is running. Also, the operating protections will not be active. Heating is OFF by default
(temp setting), while heating priority default value is ON (page 5).
7. The "Time/Date" menu allows the user to set system time and date – important
for proper filtration and dosing/salinator functioning:
Time
14:10
Day
27
Month
07
Year
18
Verification code
0 0 0 0
Wrong code
Note:
Default verification code is 1234. Only an authorized person may change the verification code.
When a wrong code is entered, changes will not be sent to the DIN module and the unit will return to original settings.
8. The "Language" menu allows the user to select the language:
Czech
a) Select ">Lights" and press "ENT/ESC" button,
Attraction
030min
b) Press "SET/SEND" button to start to set timer,
c) Press "V" to decrease operation time (1 click = -15 min),
Attraction
060min
d) Press "ꓥ" to increase operation time (1 click = +15 min),
e) Press "SET/SEND" to confirm and send changes to DIN
Attraction
090min
Attraction
000min
f) A "Sending..." message will be displayed.
In main menu, select ">Temperature" and press "ENT/ESC"
g)
button,
Press "SET/SEND" button to start to set temperature,
h)
Press "V" to decrease temperature (1 click = -1°C),
[ZAP]
i)
Press "ꓥ" to increase temperature (1 click = +1°C),
j)
[ZAP]
Press "<>" to select operation heating or cooling mode,
k)
[-08]
Press "SET/SEND" to confirm and send changes to DIN module,
l)
014
A "Sending..." message will be displayed.
m)
015
Select ">Time/Date" and press "ENT/ESC" button,
n)
Press "SET/SEND" button to set time and date,
o)
Press "V" to adjust minutes (1 click = +5 min),
p)
Press "ꓥ" to adjust hours (1 click = +1 hour),
q)
Press "<>" to move to next parameter (d/m/y),
r)
Press "V" and "ꓥ" to adjust the selected parameter,
s)
Press "SET/SEND" to confirm and send changes to DIN module,
t)
As a safety precaution, a "Verification code" must be entered.
u)
A "Sending..." message will be displayed; in case wrong code is
v)
entered the "Wrong code" message will appear.
Select ">Language" and confirm with "ENT/ESC",
a)
Press "V" to select language (CZ/EN/HR/FR/DE/ES),
b)
Press "ꓥ" to select language,
c)
Press "SET/SEND" to confirm and send changes to DIN module,
d)
A "Sending..." message will be displayed
e)
module,
7