Herunterladen Inhalt Inhalt Diese Seite drucken

Vagner Pool VArio DIN module Benutzerhandbuch Seite 22

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

7.4. Controlling the DIN module with RC module
5 outputs can be activated in the configuration menu: Filter pump with up to 4 programmable
daily cycles and 2 user regimes, Dosing (Salinator) based on filtration time,
Heating / Cooling function with regard to preset water temperature, Lights and Attraction
(e.g. counterflow) with timer.
1. Press the " " button to wake the RC from the sleeping mode.
2. Press the "V" button to enter the configuration menu:
Atraction2
>Filtration
Filtration-mode
Lights
Heating/Cooling
Atr
>Time/Date
Language
Lights-setting
Dosing
3. The "Filtration" menu allows the user to set up to 4 running cycles within 24 hours:
07:00
12:00
16:00
21:00
Note:
The first cycle starting time (in this case 07:00) also determines the starting time for salinator/dosing unit in automatic
operation mode. When setting the intervals, the first time must be lower than the second; also, you cannot pass midnight
within the same interval (e.g. 09:30-06:00). System will not accept such invalid intervals..
4. The "Filtration-mode" menu allows the user to select the operating mode of filtration:
Filtration
a)
b)
c)
d)
a)
b)
10:00
c)
15:00
d)
19:00
d)
23:00
e)
f)
a)
b)
c)
[AUTO]
g)
h)
i)
Press "V" to move down in the menu,
Press "ꓥ" to move up in the menu,
The ">" arrow indicates the selected parameter,
Press the "ENT/ESC" key to enter to selected parameter menu.
Flashing rectangle on the display indicates ongoing
information transfer between the DIN and RC modules – wait
for the communication to finish in order to change the
parameter setting.
In main menu, select ">Filtration" and press "ENT/ESC" button,
Press "SET/SEND" button to activate the timer set mode,
Press "V" to adjust minutes (1 click = +5 min),
Press "ꓥ" to adjust hours (1 click = +1 hour),
Press "<>" to move to the next timer,
Press "SET/SEND" to confirm and send changes to DIN module,
A "Sending..." message will be displayed.
">Filtration-mode" and confirm with „ENT/ESC",
Select
Press "V" to scroll through modes (AUTO/ZAP/XXCL/VYP),
Press "ꓥ" to select mode,
Press "SET/SEND" to confirm and send changes to DIN module,
A "Sending..." message will be displayed.
6
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vario rc module

Inhaltsverzeichnis