6. The "Setpoint PH" menu allows the user to change pH settings of the dosing unit:
Setpoint PH
>
7.0
7. Menu "AlrBand pH" allows the user to modify the value range for the pH alarm:
AlrBand PH
>
2.5
Note:
Other parameters such as Redox (ORP) and free chlorine (CL) can be adjusted the same way. To cancel unwanted
parameter changes, press "ENT/ESC".
8. The "TotalFlow" screen allows the user to see the total volume of filtered water. The
"ResetFlow" screen shows the volume of filtered water within a resettable time interval:
TotalFlow
0.000m3
9. The "Active alarms" menu allows the user to see active alarms on the dosing unit (OFA
stop / OFA alarm / AlrBand.
Alarms can be deactivated only on the dosing unit using the "ENTER/CAL" button.
Active alarms
OFA alarms
AlrBand
10. The "Language" menu allows the user to change the dosing station and also the DIN
module menu language. When you change the menu language of the dosing unit using
the RC module, the DIN module will automatically switch to the same language as
selected on the dosing station (available languages: CZ/DE/EN/ESP/FR/HR).
Language
>
Czech
Note:
If the dosing unit is connected to the DIN module, the menu language can only be changed in the dosing unit screen (step 4
above). The language settings in the RC main menu will be shown as "Read only" and cannot be modified. Menu language
can also be changed on the dosing station; in that case please restart the RC after the change to load the selected
language.
Select ">Setpoint PH" and press "ENT/ESC" button,
a)
Press "SET/SEND" to activate pH setting mode,
b)
Press "V" to decrease pH value (1 click = -0,1 pH),
c)
Press "ꓥ" to increase pH value (1 click = +0,1 pH),
d)
Press "SET/SEND" to confirm and send changes to DIN module,
e)
An "OK" message will appear at the bottom right of the display.
f)
Select ">AlrBand" and press "ENT/ESC" button,
a)
Press "SET/SEND" to start modify alarm range,
b)
Press "V" to decrease alarm range (1 click = -0,1 pH)
c)
Press "ꓥ" to increase alarm range (1 click = +0,1 pH)
d)
Press "SET/SEND" to confirm and send changes to DIN module,
e)
An "OK" message will appear at the bottom right of the display.
f)
ResetFlow
0.000m3
Read only
Active alarms
OFA alarms
AlrBand
Read only
Select ">Language" and press "ENT/ESC" button,
g)
Press "SET/SEND" to start language selection,
a)
Press "V" button to move down in the language list (e.g. English),
b)
Press "ꓥ" button to move up in the list (e.g. Espanol),
c)
Press "SET/SEND" to confirm and send changes to DIN module,
d)
An "OK" message will appear on the display.
e)
Select ">TotalFlow " and press
a)
"ENT/ESC" button,
"Read only" = the parameter is only for
b)
information and cannot be modified.
Select ">Active alarms" and press
a)
"ENT/ESC" button,
"Read only" = parameter is only for
b)
viewing.