49
EN
Trench construction, with masonry flushing
channel
When assembling the split base elements, ensure that the supports for the side
gratings are positioned at the edge of the trench and the cut surfaces are positioned
at the front of the next base.
06.05
Inside corners
The edge of one of the two neighbouring side grills (type 8.6 or 8.3) in the inside
corners of a infiltration or attenuation system is to be trimmed with a fine-toothed
saw as follows:
Inside corner of an infiltration/retention system from RAUSIKKO Boxes 8.6 MX / SX / HX