ENGLISH
The cooling system is pre-loaded and uses R134a coolant. The amount of coolant contained in the circuit is
480g.
At the beginning of every season, it is advisable to check that the system is full of coolant. A lack of coolant
usually causes a drop in performance. The check can be carried out by connecting a filling station and
checking the pressure levels. Should there be a severe lack of coolant, before topping up it is necessary to
locate the leakage point and find a remedy. In this case it is also advisable to check the level of lubricant in
the compressor and top it up if necessary.
At the beginning of every season, inspect every system component, including the electrical components, to
ensure that there are no anomalies.
In the event of considerable rapairs, we recommend to replace the receiver drier.
This operation is essential if the system stays open a long time, or in case of inside moisture.
34/55