4.2 • Motor adjustment (upper/lower limits)
4.2.1 • Renson motors
The end limits of the Renson motors (electronic, radio-controlled and radio-controlled,
solar) are not set in advance.
Consult the Renson motor installation instructions to set the end limits.
From the factory setting, an end point is always provided for the electronic Renson motor.
A different end point can be set via the setting cable.
4.2.2 • Detecto Rensonmotor Safety First
The end points of the Detecto Rensonmotor Safety First are not adjusted by RENSON.
They can easily and quickly be installed due to the automatic detection of the end points.
For more information, go through the installation instructions of the motor.
4.2.3 • Somfy motor
ADJUST UPPER AND LOWER END POINT SETTING AGAIN!
The upper and lower end point is adjusted in the factory.
Adjusting upper end point:
The upper end point is adjusted in the factory of Renson. The bottom bar including
sealing strip will no longer be visible. Adjust the upper end point for end use.
Adjusting lower end point:
The lower end point is adjusted at ± 400 mm from the bottom of the head box. Adjust the
lower end point completely until the bottom of the screen, with a margin of 10 mm (for the
sealing strip).