d)
Take special care when working near corners,
sharp edges, etc. Avoid allowing the accessory
tool to bounce back from the workpiece or jam.
The rotating tool attachment tends to jam at cor-
ners, sharp edges or when it bounces back. This
causes a loss of control or kick-back.
e)
Do not use chains or toothed saw blades. Such
accessories often cause a kickback or loss of con-
trol over the power tool.
Safety instructions for sandpaper grinding
a)
Do not use oversized sanding sheets; instead,
follow the manufacturer's instructions for sand-
ing sheet size. Sanding sheets that extend beyond
the sanding plate can cause injuries and lead to the
sanding sheets jamming, tearing or kicking back.
Additional safety instructions
a)
Connect a vacuum cleaner to the supplied
adapter before starting your operations.
b)
ATTENTION! Keep away sanding dust from open
fire. Dust may be explosive.
c)
Always wear safety goggles and a dust protection
mask when sanding, in particular during overhead
work and when processing critical materials!
When sanding certain materials (e. g. lead paint,
certain types of wood and metal) harmful or nox-
ious dust may be generated.
Touching or breathing in such dust may imply risks
for the operator or bystanders.
Notes regarding vibration and noise emissions
Keep the noise level and vibration to a minimum!
1.
Only use power tools which are free of defects.
2.
Maintain and clean the power tool on a regular basis.
3.
Adjust your way of working to the power tool.
4.
Do not force the power tool.
5.
Have your power tool checked if necessary.
6.
Switch off the power tool if it is not in use.
Residual risks
Even when this power tool is operated properly, residual
risks still remain. The following hazards may arise in con-
nection with the design and construction of this power tool:
a)
Damage to health resulting from hand/arm vibration
if the device is used over an extended period of
time or if it is not properly operated and maintained.
b)
Injury and property damage caused by insert tools
being flung around and unexpectedly out of/from
the electric tool due to sudden damage, wear or
improper attachment.
c)
Burns and cuts if the accessories are touched di-
rectly after use and/or with your bare skin.
m WARNING! This power tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain circum-
stances. In order to prevent the risk of serious or deadly
injuries, we recommend that persons with medical im-
plants consult with their physician and the manufacturer
of the medical implant prior to operating the power tool.
6. Technical data
Rated voltage
Nominal frequency
Power consumption
Nominal speed (oscillation rate) n
Spindle size
Sandpaper diameter
Protection class
Weight
Sound levels
Sound pressure level L
Sound power level L
Uncertainty K
Hand-arm vibration
when grinding with sanding sheet a
Uncertainty K
The hand-arm vibration value given is based on grind-
ing with sanding sheets. Other applications may result
in different values.
The noise and vibration levels have been determined in
accordance with EN 62841-1 and EN IEC 62841-2-3.
The specified vibration value has been measured in ac-
cordance with a standardised test procedure and can be
used for comparison of one electric tool with another.
The specified vibration value can also be used for an
initial estimation of the exposure.
www.scheppach.com
230-240 V~
800 - 1800 rpm
PA
WA
h
50 Hz
710 W
M14
225 mm
II
3.8 kg
78 dB
89 dB
3 dB
2.28 m/s
2
1.5 m/s
2
GB | 25