OPERATION
THEORY OF OPERATION
1. Combustion occurs in the 昀椀re pot,
supported by air introduced to and under
the 昀椀re pot. Note that some air b�ows in
from the top of the combustion chamber;
this he�ps keep ash and debris from
accumu�ating on the door.
2. The exhaust b�ower draws combustion
products from the stove and directs it out
user-insta��ed venting.
3. The auger transfers pe��ets from the hopper
to the 昀椀re pot to sustain the 昀椀re.
4. A convection b�ower propagates air a�ong
the outside of the 昀椀re box, circu�ating warm
and c�ean air into the room.
FUEL REQUIREMENT
SPECIFICATIONS FOR HIGH QUALITY PELLETS
Ca�ori昀椀c Va�ue: 5.3 kWh/kg
Density:700 kg/m3
Water Content: Max. 8% of the weight
Ash proportion: Max. 1% of the weight
Diameter:6mm
Length: Max. 30mm
Contents: 100% wood untreated and without
any bonding agents added (bark proportion
max.5%)
Packaging: �n sacks, made of
environmenta��y neutra� or bio�ogica��y
degradab�e p�astic, or from paper (2-3 �ayers
/simi�ar to cement packaging)
Pe��ets that are too �ong or too short may
resu�t in ignition di昀케cu�ty, acce�erated
creosote or f�y ash bui�dup, incomp�ete
combustion, �ow heat yie�d, and b�ackening
of the g�ass in the door.
We recommend the use of pe��et fue� according
to ENp�us® A1 or D�Np�us.
PELLET STORAGE
•
Too co�d or too hot where pe��et fue� is stored
can a昀昀ect the heat output of the stove, it is
necessary to store the fue� as dry as
possib�e and free from impurities.
•
Pe��et fue�s must be stored and transported
with care to avoid crumb�ing and sawdust
formation.
CAUT�ON: DO NOT USE CHEM�CALS OR
FLU�DS TO START THE F�RE.
CAUT�ON: DO NOT BURN GARBAGE OR
FLAMMABLE FLU�DS SUCH AS GASOL�NE,
NAPHTHA OR ENG�NE O�L.
CAUT�ON: NEVER ATTEMPT TO USE ANY
OF THE FOLLOW�NG MATER�ALS AS FUEL:
EN
7