TROUBLESHOOTING
SYMPTOM
Heater does not turn on.
The blower does not turn on during
Cleaning Cycle, Feeding Cycle, or
Lighting Cycle.
The blower does not turn on during
Stabilization Cycle.
During operation, including the
Lighting phase, the auger is not
昀椀lling the 昀椀re pot with pellets
Too much fuel in the 昀椀re pot.
The fuel can not be completely and
thoroughly burned.
Not enough fuel in the 昀椀re pot.
After the 昀椀re has started, the stove
turns off 15 minutes later.
CAUSE
Power Switch turned off.
Power Switch turned off.
Power Cord disconnected.
Fuse is blown.
This is normal.
No power in stove or in control
panel.
Mother board disconnected.
Low Temperature sensor is
broken.
No fuel in Pellet Hopper.
Auger is blocked, jammed, or
disconnected.
The feeding speed is faster than
what combustion can support.
The feeding speed is too low to
support the rate of combustion.
The pellet hopper is low on fuel.
The auger is not operating.
The 30 °C temperature switch
has triggered.
The pressure switch inside the
stove is broken
SOLUTION
Power Switch turned off.
1. Press power cord tightly into the heater
2. Ensure that the wall socket is delivering 230V.
Replace the fuse.
There is no problem, the blower does not turn on until the
stabilization cycle.
Check the power and wires.
Make sure all terminals to mother board are connected.
Replace the low temperature sensor.
Add Fuel to Pellet Hopper.
1. Unplug the unit so that it will not start suddenly and then
unblock the auger.
2. Check that the auger is not blocked. If it is blocked, remove the
cause of the jamming.
3. Check that the auger screw fastening the Auger to the motor is
secure
Increase the fan's speed to increase the rate of combustion.
Decrease the fan's speed to decrease the rate of combustion.
Check that the pellet hopper has a suf昀椀cient amount of fuel.
1. Unplug the unit so that it will not start suddenly and then
unblock the auger.
2. Check that the auger is not blocked. If it is blocked, remove the
cause of the jamming.
3. Check that the auger screw fastening the Auger to the motor is
secure.
1. Check that wires to the switch are suf昀椀ciently connected
2. Replace the 30°C temperature switch
Replace the pressure switch