SYMPTOM
Orange 昀氀ame, pellets piling up in
昀椀repot,carbon residue forming on
glass.
The 昀椀re extinguishes and the
power shuts off.
The 昀椀re extinguishes and the
power shuts off (continued).
The circulation blower continues to
operate after the stove is cool and
the fuel consumption has ceased.
The stove is not circulating a
suf昀椀cient volume of suf昀椀ciently hot
air.
CAUSE
Insuf昀椀cient air for suf昀椀cient
combustion.
No fuel in Pellet Hopper.
Auger is blocked or jammed or
disconnected.
The feeding speed is too low to
support the rate of combustion.
The 30°C temperature switch
has triggered.
Requested temperature has
been reached.
The 30°C temperature switch
has triggered.
The fuel is inadequate
The circulating blower is set too
slow or is compromised.
Heat exchange tubes or 昀氀ue
pass is dirty.
SOLUTION
1. Check that the air inlet vent in the front is open.
2. Check that the door and window gaskets are intact.
3. Check if the air inlet ducting and the combustion exhaust
ducting are blocked.
4. Increase the cross sectional area of the ducting.
5. Increase the fan's speed to increase the rate of combustion.
6. Contact the manufacturer for assistance.
Add Fuel to Pellet Hopper
1. Unplug the unit so that it will not start suddenly and then
unblock the auger.
2. Check that the auger is not blocked. If it is blocked, remove the
cause of the jamming.
3. Check that the auger screw fastening the Auger to the motor is
secure.
Decrease the fan's speed to decrease the rate of combustion.
1. Check that wires to the switch are suf昀椀ciently connected.
2. Replace the 30 °C temperature switch.
This is normal "ECO" mode behavior. The stove will automatically
switch on once the ambient room temperature drops below the
temperature that the stove is set to maintain.
1. Check that wires to the switch are suf昀椀ciently connected.
2. Replace the 30 °C temperature switch.
Use pellet fuel speci昀椀ed by this manual.
1. If the blower is broken, change out the blower
2. If the mother board which connects to the blower is broken,
change out the mother board.
Clean the heat exchanger tubes or 昀氀ue pass.
EN
19