FAN mode
Press the "MODE" button until the "FAN " indicator light comes on.
Press the "FAN SPEED" button on the remote controller to choose the fan speed.
The temperature can not be adjusted.
Do not put the duct to window.
4. UP and DOWN buttons
Used to adjust (increasing/decreasing) temperature settings in 1°C/2°F (or 1°F) increments in a range of
16°C/60°F to 30°C/88°F (or 86°F).
NOTE: The control is capable of displaying temperature in degrees Fahrenheit or
degrees Celsius. To convert from one to the other, press and hold the Up
and Down buttons at the same time for 3 seconds.
5. Display
Shows the set temperature while on Cool, or Auto mode. It shows the room temperature on DRY and
FAN modes.
Shows Error codes:
EH00-EEPROM error.
EH60-Room temperature sensor error.
EH61-Evaporator temperature sensor error.
EC52-Condenser temperature sensor error (on some models).
EH0b-Display panel communication error.
Shows protection code:
P1-Bottom tray is full--Connect the drain hose and drain the collected water away. If protection repeats,
call for service.
NOTE: When one of the above malfunctions occurs, turn off the unit, and check for
any obstructions. Restart the unit, if the malfunction is still present, turn off
the unit and unplug the power cord. Contact the manufacturer, its service
agents or a similar qualified person for service.
6. FRESH operation(on some models)
Press MODE and DOWN (-) buttons at the same time for 3 seconds to initiate FRESH feature and the
FRESH light illumiantes on some models, the LED DISPLAY shows 'On' for 3 seconds. The ion generatoris
energized and will help to purify the air inside. Press it for 3 seconds again to stop the FRESH feature and
the FRESH light turn dark on some models, the LED DISPLAY shows 'OF' for 3 seconds for some units.
7. Other features
FOLLOW ME/TEMP SENSING feature (On some models)
This feature can be activated from the remote control ONLY. There is no indicator light on the control
panel. The remote control serves as a remote thermostat allowing for the precise temperature control at
its location.
To activate the Follow Me/Temp Sensing feature, point the remote control towards the unit and press
the Follow Me/Temp Sensing button. The remote control will send this signal to the AC until press the
Follow Me/Temp Sensing button again. If the unit does not receive the Follow Me/Temp Sensing signal
during any 7 minutes interval, the unit will exit the Follow Me/Temp Sensing mode.
NOTE: This feature is unavailabe under FAN or DRY mode.