Help in case of malfunction
Error code
CN005: Bumper de-
flected
CN007: No loop sig-
nal
CN008: Loop signal
weak
CN010: Bad position
CN011: Escaped ro-
bot
CN012: Cal: no loop
CN015: Cal: outside
CN017: Cal: signal
weak
CN018: Cal: Colli-
sion
CN038: Battery
495761_c
Cause
The appliance has collided
with an obstacle and cannot
free itself (e.g. collision close
to the base station).
■
No loop signal
■
The boundary cable is
defective.
■
Loop signal is too weak.
■
Loop signal too weak
■
Boundary cable buried
too deep
■
The appliance is outside
the demarcated lawn
surface.
■
The boundary cable has
been routed in a criss-
cross pattern.
The appliance is outside the
demarcated lawn surface.
Error during calibration:
■
The appliance cannot
find the boundary cable.
Error during calibration:
■
Loop signal too weak
■
No loop signal
■
The boundary cable is
defective.
Error during calibration:
■
The appliance has collid-
ed with an obstacle.
The battery is flat:
Remedy
■
Place the appliance on the free, de-
marcated lawn surface.
■
Correct the position of the boundary
cable.
■
Check the LED on the base station.
■
Check the power supply to the base
station. Disconnect and reconnect
the power supply unit.
■
Check the boundary cable for dam-
age. Repair the defective cable.
■
Check the LED on the base station.
■
Check the power supply to the base
station. Disconnect and reconnect
the power supply unit.
■
Raise the boundary cable to the
prescribed height; attach directly to
the lawn, if necessary.
■
Place the appliance on the free, de-
marcated lawn surface.
■
Correct the position of the boundary
cable around curves and obstacles.
Eliminate the criss-crossing of the
cable.
Correct the position of the boundary ca-
ble around curves and obstacles.
■
Check the power supply to the base
station. Disconnect and reconnect
the power supply unit.
■
Place the appliance in the pre-
scribed calibrating position; align
precisely at right angles. Appliance
must be able to drive over the
boundary cable.
■
Place the appliance in the pre-
scribed calibrating position; align
precisely at right angles.
■
Check the power supply to the base
station. Disconnect and reconnect
the power supply unit.
■
Check the boundary cable for dam-
age.
Remove the obstacle.
51