Help in case of malfunction
Error code
CN005: Bumper de-
flected
CN007: No loop sig-
nal
CN008: Loop signal
weak
CN010: Bad position
CN011: Escaped ro-
bot
CN012: Cal: no loop
CN015: Cal: outside
CN017: Cal: signal
weak
CN018: Cal: Colli-
sion
CN038: Battery
495761_c
Cause
The appliance has collided
with an obstacle and cannot
free itself (e.g. collision close
to the base station).
No loop signal
The boundary cable is
defective.
Loop signal is too weak.
Loop signal too weak
Boundary cable buried
too deep
The appliance is outside
the demarcated lawn
surface.
The boundary cable has
been routed in a criss-
cross pattern.
The appliance is outside the
demarcated lawn surface.
Error during calibration:
The appliance cannot
find the boundary cable.
Error during calibration:
Loop signal too weak
No loop signal
The boundary cable is
defective.
Error during calibration:
The appliance has collid-
ed with an obstacle.
The battery is flat:
Remedy
Place the appliance on the free, de-
marcated lawn surface.
Correct the position of the boundary
cable.
Check the LED on the base station.
Check the power supply to the base
station. Disconnect and reconnect
the power supply unit.
Check the boundary cable for dam-
age. Repair the defective cable.
Check the LED on the base station.
Check the power supply to the base
station. Disconnect and reconnect
the power supply unit.
Raise the boundary cable to the
prescribed height; attach directly to
the lawn, if necessary.
Place the appliance on the free, de-
marcated lawn surface.
Correct the position of the boundary
cable around curves and obstacles.
Eliminate the criss-crossing of the
cable.
Correct the position of the boundary ca-
ble around curves and obstacles.
Check the power supply to the base
station. Disconnect and reconnect
the power supply unit.
Place the appliance in the pre-
scribed calibrating position; align
precisely at right angles. Appliance
must be able to drive over the
boundary cable.
Place the appliance in the pre-
scribed calibrating position; align
precisely at right angles.
Check the power supply to the base
station. Disconnect and reconnect
the power supply unit.
Check the boundary cable for dam-
age.
Remove the obstacle.