Precision Time Protocol (PTP)
41.2.7

ptp v2-boundary-clock sync-interval

Configure the Sync Interval in seconds {0.25|0.5|1|2}.
Mode: Interface Range Mode
Privilege Level: Administrator
Format: ptp v2-boundary-clock sync-interval <P-1>
Parameter Value
0.25
P-1
0.5
1
2
41.2.8

ptp v2-boundary-clock announce-timeout

Configure the Announce Receipt Timeout (2..10).
Mode: Interface Range Mode
Privilege Level: Administrator
Format: ptp v2-boundary-clock announce-timeout <P-1>
Parameter Value
2..10
P-1
41.2.9

ptp v2-boundary-clock asymmetry

Set the asymmetry of the link connected to this interface
Mode: Interface Range Mode
Privilege Level: Administrator
Format: ptp v2-boundary-clock asymmetry <P-1>
Parameter Value
-
P-1
2000000000..200000
0000
41.2.10 ptp v2-boundary-clock v1-compatibility-mode
Set the PTPv1 Hardware compatibility mode {auto|on|off}.
Mode: Interface Range Mode
Privilege Level: Administrator
Format: ptp v2-boundary-clock v1-compatibility-mode <P-
1>
Parameter Value
on
P-1
off
auto