Herunterladen Inhalt Inhalt Diese Seite drucken

Clock; Clock Set; Clock Timezone Offset; Clock Timezone Zone - Hirschmann RM CLI HiOS-2S RSPS Referenzhandbuch

Command line interface; rail switch power smart
Inhaltsverzeichnis

Werbung

Clock

7
Clock
7.1
clock
Configure local and DST clock settings.
7.1.1

clock set

Edit current local time.
Mode: Global Config Mode
Privilege Level: Administrator
Format: clock set <P-1> <P-2>
Parameter Value
YYYY-MM-DD
P-1
HH:MM:SS
P-2
7.1.2

clock timezone offset

Local time offset (in minutes) with respect\nto UTC (positive values for loca-
tions east of\nGreenwich).
Mode: Global Config Mode
Privilege Level: Administrator
Format: clock timezone offset <P-1>
Parameter Value
-780..840
P-1
7.1.3

clock timezone zone

Edit the timezone acronym (max. 4 characters).
Mode: Global Config Mode
Privilege Level: Administrator
Format: clock timezone zone <P-1>
Parameter Value
string
P-1
7.1.4

clock summer-time mode

Configure summer-time mode parameters.
Mode: Global Config Mode
Privilege Level: Administrator
Format: clock summer-time mode <P-1>
102
Meaning
Local date (range: 2004-01-01 - 2037-12-31).
Local time.
Meaning
Edit the timezone offset (in minutes).
Meaning
Edit the timezone acronym (max 4 charac-
ters).
7.1 clock
RM CLI HiOS-2S RSPS
Release 3.0 01/2014

Werbung