Error Code
2
3
4
7
8
10
11
17
18
19
20
Parameter configuration
Press the M button for approximately 3 seconds to enter the set-up menu; press the M button for approximately 3 seconds to
exit the set-up menu and confirm the entered parameters.
Select the desired value of the individual parameter by pressing the + or – buttons and confirm it by pressing the M button
(quickly to access the next configurable parameter, or for approximately 3 seconds to exit the configuration menu by
confirming the entered parameters.).
The sequence of parameters that can be configured is shown below:
P1 - Unit of measurement:
Press the + or – buttons to select the unit of measurement for the speed and travel data displayed on the display:
International metric system (Km/h and Km) or British imperial system (MPH and Mile)
P2 - User password ON/OFF display:
Available options = on / off
OFF = selecting "off", confirmed by pressing the M button, excludes the user password request (identification code) to allow
the user to access and activate the display and allow full control of all the functions provided for the electrically power
assisted cycle.
The display controls and functions will be immediately accessible after pressing the ON button.
ON = by selecting the data "on", confirmed by pressing the M button, the configuration parameter is enabled which provides
for the activation of the display and access to all the functions provided for the complete management of the pedal-assisted
bicycle exclusively after entering a user password (identification code).
Display controls and functions, after pressing the ON button, will only be accessible after entering the user password
previously set (P3).
P3 - User password:
Parameter only displayed after the "ON" option has been selected which allows the user to enable the display access
configuration exclusively by entering the password (numeric identification code consisting of 4 digits) previously set and
confirmed as follows:
-
select the 4 digits which make up the password by pressing the + and – buttons and confirm them individually by
pressing the ON/OFF button
-
confirm the 4-digit identification code by pressing the M button for approximately 3 seconds to exit the configuration
menu, confirming the entered parameters.
0000 - Password to set the system parameters accessible exclusively for after-sales support; in case abnormal data relating
to speed (Km/h and Km) and travel (MPH and mile) are highlighted on the display, contact the after-sales technical support
service to receive appropriate help: www.argentoemobility.com/en/support/
Malfunction when using the walk assist mode lever
Brake sensor malfunction
Control unit malfunction
Control unit overheated
High voltage protection (voltage above threshold)
Motor malfunction (excessive power consumption)
Motor hall sensor malfunction
Display-control unit wiring communication malfunction
Display-control unit programming communication malfunction
Brake sensor malfunction
Motor block
Malfunction description