9. Maintenance
m Warning! Pull out the mains plug before carrying
out any setting, servicing or repair work!
General maintenance tasks
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub
the device clean with a clean cloth or blow it off with
compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can
penetrate the device interior.
• All moving parts must be re-lubricated periodically!
Carbon brushes
• If excessive sparks are formed, have an electrician
check the carbon brushes. Attention! The carbon
brushes must only be replaced by an electrician.
Service information
With this product, it is necessary to note that the fol-
lowing parts are subject to natural or usage-related
wear, or that the following parts are required as con-
sumables.
Wearing parts*: Carbon brushes, drill, chisel
* may not be included in the scope of delivery!
Spare parts and accessories can be obtained from
our Service Centre. To do this, scan the QR code on
the front page.
10. Storage
Store the device and its accessories in a dark, dry
and frost-free place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Store the power tool in its original packaging.
Cover the power tool to protect it from dust or mois-
ture.
Store the operating manual with the power tool.
11. Electrical connection
The electrical motor installed is connected and ready
for operation.
The connection complies with the applicable VDE
and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these regu-
lations.
Damaged electrical connection cables
The insulation on electrical connection cables is of-
ten damaged.
Causes are:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables
must not be used and are life-threatening due to
the insulation damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables of the same designation.
The printing of the type designation on the connec-
tion cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of C 16A or K 16A for products with a high start-
ing current (from 3000 watts)!
AC motor
• The mains voltage must be 220- 240 volts/50 Hz.
• Extension cables up to 25 m long must have a
cross section of 1.5 square millimetres, and those
over 25 m long must have a cross section of at least
2.5 square millimetres.
• The mains power connection is protected with a
16A slow-blow fuse.
Connection type X
If the mains connection cable of this product is dam-
aged, it must be replaced by a specially prepared
mains connection cable which can be obtained from
the manufacturer or its service department.
12. Disposal and recycling
Notes for packaging
www.scheppach.com
The packaging materials are
recyclable. Please dispose of
packaging in an environmen-
tally friendly manner.