To use Duty cycle function, turn the rotary switch to the DCV position, then press F1 to
change measuring mode.
Measuring Resistance
CAUTION
• To avoid possible damage to the meter or to the equipment under test, disconnect
circuit power and discharge all high voltage capacitors before measuring resistance.
The ranges of measuring resistance are 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, and 40MΩ.
The test leads may be add 0.1Ω to 0.2Ω of error to resistance measurements. To test
the leads, touch the probe tips
together and read the resistance of the leads. For best
accuracy, you can use the relative (Δ) mode to automatically subtract this value.
High-resistance (>10MΩ) readings are susceptible to electrical noise. To smooth out
most noisy readings, enter the MAX/MIN recording mode; then step to the average (AVG)
reading.