Herunterladen Diese Seite drucken

Bosch BTH-RAD Bedienungsanleitung Seite 21

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
Radiator thermostat II [+M]
Error displays
The device displays errors that require a response in the display area (3).
E01 – Low battery level
Display Description
The battery
level of the
device is low.
E02 – Sensor error
Display Description
An error has
occurred in
the internal
temperature
sensor.
E03 – Calibration error
Display Description
Error during
calibration
↑Contents
8-750-002-924 | V001 | 08/2024
Recommended action
Check the device for external damage. Try a
restart by briefly removing and reinserting a
battery. If the device is not damaged and the
error persists after restarting, contact support.
Recommended action
Check the device for external damage. Try a
restart by briefly removing and reinserting a
battery. If the device is not damaged and the
error persists after restarting, contact support.
Recommended action
Check that the device is correctly mounted
on the radiator valve. If in doubt, unscrew the
thermostat again, clean the thread on the valve
if necessary and remove any obstructions on the
radiator. Check whether the valve pin is stuck.
When screwing the thermostat onto the valve,
hold the housing firmly in your hand in the
desired orientation and turn the fastening ring
by hand as far as it will go on the valve. No tools
are required. It should no longer be possible to
move or turn the device.
If adapters are used, make sure that the correct
type is used.