8. Parameter Description
Heat Sink Temperature Level
GB
Brake Release Time
Crawl Path Optimization
Rated Speed V
N
Crawl Path Optimization
Speed V
1
Crawl Path Optimization
Speed V
2
GB 36
Dependent on the temperature level the relay output for the control
-cabinet fan control (X2.20 / X2.21 / X2.22) is switched.
current heat sink temperature > LF.66
current heat sink temperature < LF.66 - 5 K
Unit:
Value range:
Factory setting:
Unit:
Value range:
Factory setting:
Adjusted value:
Unit:
Value range:
Factory setting:
V
V
N
V
E
Unit:
Value range:
Factory setting:
Function see parameter LF.71.
Unit:
Value range:
Factory setting:
Function see parameter LF.71.
degreesCelsius
20...50 °C
40 °C
seconds
0.300...3.000 s
0.300 s
0.300 s
centimeter
0.0...200.0 cm
0.0 cm
LF.71
LF.71
deceleration point
centimeter
0.0...200.0 cm
0.0 cm
centimeter
0.0...200.0 cm
0.0 cm
relay picks up
relay drops out
t