Operation
4
Operation
4.1
General
Do not pull off fixed loads.
In the event of a power failure, disconnect the load immediately if possible.
Only suction and lift suitable loads (check inherent stability and surface density).
Only place the load on a clear, level surface. Otherwise they may slip when released.
Do not release the load until it is fully and securely in place.
Keep hands away from the load when releasing
Always apply an even load to the suction surfaces.
4.1.1 Lifting loads
Position the device directly above the load.
Place the device on the load. Ensure that the load is evenly distributed.
Switch on the device
o Without T-handle: On/off head must be permanently pressed.
o With T-handle: Press the button on the wired remote control once.
The load is now sucked in.
When lifting, ensure that only one piece of the goods to be lifted is lifted at a time. Carefully
remove any other adhering parts with a suitable tool before continuing to lift the part. Do not
loosen with your hands, risk of crushing!
4.1.2 lacing loads
Lower the load and place it safely on a clear, level surface so that it cannot slip or tip over.
To release the suctioned load:
o Without T-handle: Release the on/off head.
o With T-handle: Press the button on the wired remote control once.
Load is now being replaced.
58500018