Herunterladen Diese Seite drucken

ABB ProcessMaste FEX300 Schnittstellenbeschreibung Seite 32

Werbung

Block-Übersicht
Relative
Index
58
DO_PV_COUNTER_RESET
59
DO_PV_FLOW_TO_ZERO
60
DO_PV_SYSTEM_ZERO_ADJUST
61
DO_PV_COUNTER_STOP
62
DO_PV_DUAL_RANGE
63
DO_PV_BATCH_START
64
FLOW_RATIO
65
FLOW_VELOCITY
66
FLOW_VELOCITY_UNITS
67
VOLUME_FLOW_USER_UNIT_FACTOR
68
VOLUME_FLOW_USER_UNIT_TYPE
69
VOLUME_FLOW_USER_UNIT_STRING
70
SENSOR_LOCATION_TAG
71
SENSOR_TAG
72
TX_LOCATION_TAG
73
TX_TAG
74
Q_MAX
75
Q_MAX2
76
DUAL_RANGE_SELECTION
77
DAMPING
78
DENSITY
79
LOW_FLOW_CUTOFF_HYSTERESIS
80
METER_MODE
81
NOISE_REDUCTION
82
READ_ONLY_SWITCH
83
UZA_ADJ_PROGRESS
84
UZA_ADJ_FAIL_INFO
32
Parametername
Object
Type
Record
DS-102
Float
Simple
Unsigned16
Float
Unsigned8
VisibleString
Float
Unsigned8
Float
Unsigned8
FEX300, FEX500
Data Type
Store Bytes
D
2
D
2
D
2
D
2
D
2
D
2
D
4
D
4
S
2
S
4
S
1
S
8
S
20
S
20
S
20
S
20
S
4
S
4
S
1
S
4
S
4
S
4
S
1
S
1
S
1
D
1
D
1
COM/FEX300/FEX500/PB-DE
Access
r
r
r
r
r
r
r
r
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r,w
r
r

Werbung