Herunterladen Inhalt Inhalt Diese Seite drucken

Retrofit Image Input And Output Signals; Input Signals (From Robot To Welding Machine) - Fronius Ri Fb Inside/I Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für RI FB Inside/i:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Retrofit Image Input and Output Signals

Input Signals
The signals listed below are available from firmware V1.8.5 for all Inside/i sys-
(from robot to
tems.
welding machi-
ne)
Only in Job mode operating mode
44
Seq. no
Signal designation
E01
Welding on
E02
Robot ready
E03
Operating modes bit 0
E04
Operating modes bit 1
E05
Operating modes bit 2
E06
E07
E08
E09
Gas test
E10
Wire feed
E11
Wire-return
E12
Error quit
E13
Position searches
E14
Purge the welding torch
E15
E16
E17 - E24
Job number
E25 - E31
Program number
E32
Welding simulation
E17 - E31
Job number
E32
Welding simulation
E33 - E40
Set power value - Low byte
E41 - E48
Set power value - High byte
Arc length correction, set value
E49 - E56
Low byte
Arc length correction, set value
E57 - E64
High byte
E65 - E72
E73 - E80
Pulse or dynamic correction
E81 - E88
E89 - E96
E97
SynchroPulse on
Range
Action
High
High
See table
Value
High
range Operating
High
modes
on page
45
High
High
High
High
High
High
High
0 to 99
1 to 127
High
0 to 999
High
0 to 65535
(0 to 100%)
0 to 65535
(-30 to +30%)
0 to 255
(-5 to +5%)