NOTE!
Whenever changes are made to the DIP switch settings, the interface must be
restarted in order for the changes to take effect.
(Restart = interrupting and restoring the power supply or executing the corre-
sponding function in SmartManager)
Configuring the
Upon delivery the configured node address is 0. The node address can be confi-
Node Address
gured in two ways:
-
-
NOTE!
If the node address is set to higher than 0 with the dip switch, the relevant node
address will be configured to the range of 1 to 63 after restarting the robot in-
terface.
A node address previously configured by a configuration tool is overwritten.
NOTE!
If configurations have already been made, the network configurations can be
restored to factory settings in two ways:
The Website of
The welding machine has its own website, the SmartManager.
the welding ma-
As soon as the welding machine has been integrated into a network, the Smart-
chine
Manager can be opened via the IP address of the welding machine.
Depending on the system configuration and software upgrades, the SmartMana-
ger may contain the following entries:
-
-
-
-
-
-
-
-
Node addresses in the range of 1 to 63 can be configured with the dip switch.
If node address 0 is kept on the dip switch, the node addresses in the range
of 1 to 127 can only be configured with the following configuration tools:
-
SmartManager
set all dip switches back to 0 and restart interface
or
using the
Restore factory settings
Overview
Update
Screenshot
Save and restore
Function packages
Job data
Overview of characteristics
RI FB INSIDE/i
Englisch (US)
button in SmartManager