sure that the lifting station is suitable for the electricity sup-
ply available at the installation site.
The lifting stations require no additional motor protection.
Connect the units to the mains supply.

6. Installation

The operator has to prevent damage through the flood-
ing of rooms caused by defects of the pump through the use
of appropriate measures (e.g. installation of alarm units,
backup pump or the like).
Install the disposal unit SEKAMATIK 10 E 6M horizontal on
an even floor. In order to allow low noise operation, the dis-
tance between the unit and the wall should be 0,5 cm min.
(Pic 1) Place the toilet in front of the unit and push the WC-
spigott into the socket of the box. Please make sure that the
front of the tank will not be pressed in.
To connect additional sanitary units (e.g. a shower) install a
DN 40 discharge hose from the outlet of the sanitary unit to
one of the inlets of the box. Please pay attention to give the
required gavity fall.
.
(Pic.2) Remove the cap, which is screwed on the inlet and
take the black sealing ring and the white plastic ring out of
the cap.