Herunterladen Inhalt Inhalt Diese Seite drucken

Storage - Elmo Rietschle V Serie Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für V Serie:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

DANGER
CAUTION
NOTE
For a description of the safety instructions, see chapter 2.9.
The following steps must be observed during dismantling and decommissioning:
1.
Switch off the pump and release the drive.
2.
Switch off the power supply and secure it against being switched on again unintentionally.
3.
Disconnect the supply line of the drive.
4.
Shut off media lines and divert pressure differences if necessary.
5.
Disconnect the media lines from the pump.
6.
Clean the pump thoroughly
7.
Disassemble the pump in reverse order of assembly or according to separate disassembly
instructions. Loose parts must be secured to prevent them from tipping over or falling down.
8.
Protect the pump from further contamination.

8.11 Storage

The following requirements for the storage location must be observed in order to store the unused pump in a
proper condition over a longer period of time. If the following requirements are not observed, the pump may
be damaged. Storage without oil filling is recommended. The storage location must
• the storage place must be dry and clean
• the storage place must be level
• the storage place must be protected from sudden changes in temperature and humidity
• the storage location must be protected from salt spray, industrial gases, corrosive liquids, rodents and
fungal attack
Restocking
If the pump is to be stored for a longer period of time (more than two months) after use, the following steps
must be observed.
1.
Ensure that the pump is free of water or water vapour.
2.
To do this, close the intake. Set the vacuum regulating valve to the maximum vacuum.
3.
Allow the pump to run for 30 minutes after reaching operating temperature. Only draw in a small
amount of dry ambient air.
4.
Immediately after switching off the pump, seal all inlets and outlets with sealing plugs.
5.
Silica gel packets must be placed inside the filter housing. Attach a warning sticker so that the
packets can be removed again before commissioning.
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Risk of injury from slipping, tripping and falling
Wear suitable personal protective equipment (PPE for short).
MAINTENANCE, SERVICING AND DISMANTLING
www.elmorietschle.com © Gardner Denver Schopfheim GmbH
Tel. 071 918 60 60, Mail: v-g@prematic.ch
37
|

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

V-ktr 61V-ktr 81V-ktr 101V-ktr 141

Inhaltsverzeichnis