8.4.5
Bearing lubrication (KTR 101+141)
The pump must be relubricated at regular intervals.
The two lubrication points are located behind the air guide cover. Loosen the screws and remove the cover.
For optimum grease distribution, the pump must be regreased during operation.
Switch on the pump and fill it with a grease gun.
Fig. 13 Lubrication
Tab. 9 Bearing lubrication table
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Series
KTR 101
KTR 141
1 stroke ≈ 0.5g fat
MAINTENANCE, SERVICING AND DISMANTLING
Number of strokes/grease nipples
10
15
www.elmorietschle.com © Gardner Denver Schopfheim GmbH
Tel. 071 918 60 60, Mail: v-g@prematic.ch
33
|